POLVISION
Producent systemów
telewizji przemysłowej
















Szybki kontakt

info@polvision.pl
71 327 45 94
503 081 146


Media




Oficjalni partnerzy

Geovision - video surveillance systems

Network Optix - open video platform

AnyVision - making AI accessible to the world

VCA Technology - we do video analytics

HikVision - technology leader in network cameras

Dahua - leading video surveillance solution provider


Twój adres IP

80.49.208.199


POLVISION 2004-2020
Wszelkie prawa zastrzeżone.
Wyszukiwanie

Produkty >



   PV-PS56VDC/1.2A          (link)      

   

Zapisz jako Word

   Kategoria produktu: Systemy transmisji > koncentryk > extendery sieci Ethernet (IP) > Drukuj (PDF)

 

Zasilacz impulsowy 56VDC, 1.2A (max 67W) o niskim poziomie zakłóceń

  • OUTPUT
    SAFETY MODEL NO PF-560120 DC VOLTAGE 56V RATED CURRENT 1.2A CURRENT RANGE 0-1.2A RATED POWER 68W RIPPLE& NOKISE(max.) Note.3 100mVp-p VOLTAGE TOLERAN CE Note.4 ±5% LINE REGULATION  Note.5 ±1% LOAD REG ULATION Note.6 ±5% SETUP,RISE TIME Note.8 1000ms,50ms/115VAC at full load HOLD UP TIME(Typ) 20ms/230VAC 10ms/115VAC at full load
  • INPUT
    VOLTAGE RANGE  Note.9 90-264VAC 100-240VDC FREQUENCY CTOR(Typ) 50-60HZ EFFICIENCY(Typ.) 87% AC CURRENT(Typ.) 1.5A/115VAC&230VAC INSRUSH CURRENT(max.) 50A/230CAC LEAKAGE CURRENT(max) 1mA/240VAC
  • PROTECTION OVERLOAD
    120-300% reated output power Protection type:Hiccup mode,recovers automatiocally after condition is removed
  • ENVIRONMENT
    WORKING TEMP 0~+40℃(Refer to "Derating Curve")
    WORKING HUMIDITY 0~85% RH non-condensing STORAGE TEMP.,HUMIDITY ,-10~+60℃,10~80%RH
    TEMP.COEFFICIENT ±0.03%/℃(0-40℃)
    VIBRATION
    10-500HZ,2G 10min./1cy cle,period for 60min,each along X,Y,Z axe
  • OTHER
    MTBF 1000K Hrs min,MIL-HDBK-217F(25℃)
    DIMENSION 115.06*55.06*32mm(L*W*H)
    PACKING 0.28kg,50PCS/14.0KG/1CUFT
  • CONNECTOR PLUG 5.5*2.1*10mm
  • NOTICES
    1.All parameters are specified at 230VAC input,rated load,25℃ 70% RH ambient.
    2.DC voltage:The output voltage set at point measure byplug terminal & 50% load
    3.Ripple& noise are measured at 20MHz by a 12 twisted pair terminated with a  0.1uf &47uf capacitor.
    4.Tolerance:includes set up tolerance,line regulation,load regulation.
    5.Line regulatiion is measured from low line to high line at rated load.
    6.load regulation is measured from 10% to 100% rated load.
    7.The power supply is considered as an independent unit,but the final equipment  still need to re-confirm that the whole system complies with the EMC directives.
    8.Length of set up time is measured at first cold start.Turning ON/OFF the power  supply may lead to increase of the set up time.
    9.Derating may be needed under low input voltages,Please check the derating curve  for more edtails.

 

Powiększ